Defibrillator Analyzers are used for testing the functionality, accuracy, and performance of Defibrillators. Pacer Testers evaluate pace outputs.  

 

Defibrillator Analyzer

DA-2006
(also available with Pacer Analyzer / DA-2006P)
 

Variable Load Module for BCB Defibrillator Analyzers

DA-2006-VL
 

Pacemaker Tester - External

EXPMT-2000

The DA-2006 is a microprocessor-based analyzer that is used in the testing of defibrillators. It measures the energy output and provides information about the pulse. It is used on manual, semi-automatic and automatic defibrillators with monophasic, biphasic and pulsed biphasic outputs.

NOTE: This instrument is intended for use by trained service technicians.

Features:
• Simple to operate
• Graphics display with simultaneous detailed status of parameters and scrolling control of options
• On screen viewing of defibrillator and pacemaker waveforms
• Drop down choice screens list all options for parameters
• Monophasic and biphasic compatible
• 5000 V, 1000 joule capacity
• High and low ranges
• Cardioversion delay measurement
• Charge time measurement
• Waveform storage and playback
• 10 universal patient lead connectors
• 25 pin connector for Centronics printer
• 9 volt battery power
• Low battery indicator
• Available battery eliminator
• Display backlight
• Full remote operation via rs-232
• Flash programmable for upgrades
• Auto sequence testing

The Biomedical DA-2006P Defibrillator Analyzer Features:
• Tests monophasic, biphasic and pulsed biphasic defibrillators
• Tests AEDs
• Pacer testing capability
• Internal paddle adapters
• Printer output
• Battery or line power

 

DA-2006-VL, works in conjunction with DA-2006 Series Defibrillator Analyzers, providing Variable Loads used when testing Defibrillators to assure the proper electrical current is delivered to the heart, per IEC 60601-2-4 and AAMI DF80 standards. Automatic detection of loads, no settings to change or configure in the DA-2006/P. Ensure that the correct load is selected in the Defibrillator output pulse measurement.

If you already own a DA-2006 or DA-2006P, you can update your software for free to be compatible with the DA-2006-VL.

NOTE: This instrument is intended for use by trained service technicians.

Features:
• Pulsed Biphasic, Biphasic and Monophasic Compatible
• Fully AED Compatible
• 5000 V, 1000 Joule Capacity
• Smart Loads, no settings to change in DA-2006 or DA-2006P
• 25-200 ohm Loads, 25 ohm Steps

 

The EXPMT-2000 External Pacemaker Analyzer has evolved from the best selling EXPMT-100 Pacer Analyzer. It will test and verify all the functions of any external pacemaker including Transvenous, Transthoracic and A-V Sequential models.

The operation is menu driven via eight tactile keys and a large four line LCD display. Test measurements are simultaneously presented on the display. Five ECG snaps are standard along with an RS-232 serial port that allows for printing both a heading and test measurements on a separate serial printer. Information may also be sent to any Windows based handheld computer. The external test load has twelve user selectable loads from 100 to 1000 ohms for use with transcutaneous pacers.

The EXPMT 2000 with its new look, new features, new controls and new display combine to make it the easiest to use and the most comprehensive pacer analyzer available. The EXPMT 2000 has been enabled to test all Medtronic pacers including the 5348 and the 5388.

Features:
• Easy to Use, Fast amp; Accurate
• Portable
• Dependable
• Large 4-line LCD Display
• 12 Selectable Test Loads
• 5 ECG Test Leads
• RS-232 Interface
• Print Key
• Accurate Tests
• Demand Sensitivity Tests
• Sensed and Paced Refactory
• 60 / 50 Immunity Tests
• Pulse Energy amp; A-V Interval

Includes:
• Hard carry case (p/n: 301)
• AC adapter (p/n: 302)
• 2 Medtronic pacer cables (p/n: 908)
• Load Box (p/n: 950-Load)
• Insulated banana plugs (p/n: 6383-02)


Talk to a MasTec Sales Engineer

   